Atomic Absorption Spectrophotometer Model-LI-5310

LI-5310-p

Lasany presents a wide range of Quality Equipment required in day-to-day function of a Chemical Laboratory to Advanced Instruments used for Quality Assurance/Control and Research. Our Atomic Absorption Spectrophotometer offers a State-of-the-art technology bundled with many features as a complete economical package.

SALIENT FEATURES

  1. Advance technology for intelligent stray light measure and correction
  2. Original Optical Noise Reduction & Automatic measurement and stray light dynamic detected without any reference materials and incremental cost. It improves instrument’s optical performance, optical  precision, linear range and background correction effectively
  3. Develop internal lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and influence to instrument's stability. Meanwhile it will prolong working life of the lamps. Normal hallow cathode lamps are highly economical than special lamps
  4. Original ''Hg lamp-regent'' gradient measurement. we established an exact mathematical model to estimate “single beam linear and balance "specification. This technology provided a fast and
  5. economic method for instrument self testing system. It also established a brand new method to improve instrument's detection Performance.
  6. Numerous technological innovation and renewal such as design aesthetics, element lamp multi dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on.

OPTIONS:

  1. Graphite Furnace
  2. Auto-Sampler for Graphite Furnace
  3. Hydride Generator
  4. Wide range of Hollow-Cathode Lamps(Single/Multi Element)

Technical Specifications

Optical System

Instrument Type

Single Beam Reflection Achromatic Optics System

Monochromator

Aberration Corrected Czerny-Turner

Dispersion elements

Grating system 1200 line/mm characterization area 40mm2

Scintillation wavelength 250nm

Bandwidth

0.1,0.2,0.4,1nm(4 step auto switching)

WL Range

190-900

WL Accuracy

±0.2

WL Repeatability

±0.1 nm max

Resolution

Min 3 lines (279.5 & 279.8 peak and Valley )

HCL housing

Standard 4 lamp turret .

( 1 for measurement , 3 in warm-up mode ) Option :- 6 Lamp / 8 Lamp Turret .

Gas control

Automatic control & optimization (flow/pressure)

Safety measures

Gas Leak check, prevention of gas release when flame dies out,

prevention of flashback through pressure monitoring.

Photometric properties

Measurement

Aberration-corrected Czerny-Turner mounting

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift

(Cu) +-0.003A/30min

Dynamic Baseline Drift

(Cu) +-0.006A/30min

Background Correction

High speed self-reversal (BGC-SR) method: High

speed D2 lamp method (BGC-D2)

Atomization System

Flame

Characteristic Concentration

(Cu) 0.025 μg/ml max

Detection limit

(Cu) 0.004 μg/ml max

Precision

RDS =0.5%

Burner

Air cooled Titanium

Nebulizer

High-efficient Nebulizer

Spray chamber

Anticorrosion material

Safety measures

Flame fuel gas, power assisted gas abnormal pressure protection

Data Process

Test Manner

Flame , flame emission .

Concentration

standard curve, standard addition, interpolation

Times of repetitive

Measurement 1-30 times, Average Value of A&C

Report Print

parameters, date result

Other

Dimension & Weight

(Flame)

700×420×550 mm; 103 kg(approx.)

Power (Main unit with(Flame)

AC 220 V ±10%, 50 Hz without sharp fluctuations.

Working Temperature range

10~300C

Working Humidity range

40%~85%

Â